FMC-60

The FMC-60 is a multi-channel controller that has been designed to operate in the full range of environments from commercial premises through to heavy industrial applications which may require hazardous area sensing.

The FMC-60 system operates on a 4 core (addressable) or 2/3 core (direct) cable network and has the capacity to monitor up to 64 addressable and 16 direct sensors of various gas types.

Each gas sensor continuously monitors the atmosphere, reporting any hazardous conditions to the control unit, for display by the alpha numeric screen indicating the reporting sensor, gas type, concentration and alarm status. Alarm levels that are exceeded will automatically activate a variety of signal outputs including analogue/digital data and user selectable relays.

Key Features

  • Up to 64 addressable sensors
  • 1-16 direct 4~20mA sensors - 2/3 wire
  • Either or both types of sensors
  • Single 4 core sensor network (addressable)
  • Parameter set up via pc or front panel
  • On screen text description of sensor locations
  • 3 alarm levels
  • Event - data logging - internal 99 event
  • Low cost installation
  • Repeater panel - option
  • 64 Additional relays - option
  • Continuous data logging via pc - option
  • Addressable relay board - option
  • One man calibration utilising peak readings
  • Automatic safety check diagnostics/system surveillance
  • Combi Plus, up to 128 addressable sensors per panel

Specifications*

Sensor Points

  • 1-64 addressable – Can bus – and/or 16 direct 4~20mA
  • Combi Plus - 128 addressable

Measurements

  • Combustible Gas - L.E.L., % vol, ppm
  • Toxic Gas - ppm, % vol
  • Oxygen - % vol Depletion/Enrichment
  • Any 4~20mA input signal

Indicators

  • Dot matrix LCD 4 line 40 character - indicating sensor location, gas type, concentration (rising or falling), alarm status, system fault, line fault, sensor fault, inhibit, real time clock, event memory Red LED - global alarm, Amber LED - global fault, Amber LED-inhibit

Outputs

  • 8 user selectable zone/voting – time ON/OFF delay relays
  • NE/ND option
  • Relay contacts - 4 D.P.C.O / 4 S.P.C.O. rated @ 5A-230v AC
  • Factory set - 1 common low alarm D.P.C.O
  • 1 common high alarm D.P.C.O
  • 1 common overange S.P.C.O
  • 1 common fault alarm S.P.C.O
  • General alarm relay - resetable S.P.C.O. - for sounders etc.
  • Optional - 64 relays - programmable with pattern/event
  • Optional - addressable 4 way relay unit
  • 2 channel 4~20mA - assignable to any sensor
  • RS232 data log - event log
  • Modbus - RS485 x2

Audible Alarm

  • Alarm/Fault - permanent mute option

Power

  • 230/115v AC or 24v DC
  • Control unit 7.5w quiescent 17w full alarm
  • Sensor - 2.5w
  • Internal power supply - 20 sensors max
  • - 21+ sensors - PS10 Power Pack

Sensor Cable

  • Main network - 4 core (2 power - 2 comms)

Addressable

  • 2/3 core
  • 1.5mm2 screened max length 1km

Miscellaneous

  • Enclosure cable entry - bottom, rear, top
  • Remote reset/mute
  • Front panel button – key lock
  • Repeater panel
  • 16 way 4~20mA catalytic converter panel
  • LED indication – Con fail, Modbus fail, MPU fail
  • Password protection - user mode/engineers mode
  • LCD and LED dimming

Environmental

  • Control unit - IP52
  • Operating temperature -10 + 50°C

Dimensions

  • 315W x 265H x 95D / 12.4W x 10.4H x 3.7D" - Combi panel
  • 315W x 265H x 95D / 12.4W x 10.4H x 3.7D" - Auxiliary power pack

Weight

  • 4.95Kg / 10.91 lbs.

*Specifications are subject to change